86-312-8695888
86-13722963501
info@hbysindustry.com
afrikano
albana
Amhara
la araba
la armena
Azerbajĝana
eŭska
Belarusian
bengala
bosnia
bulgaro
kataluna
Cebuano
korsika
kroata
ĉeĥa
dana
nederlanda
la angla
Esperanto
estona
finna
franca
frisa
galego
kartvela
germana
greka
Gujaratio
Haitian Creole
hausa
havajano
la hebrea
Ne
Miao
hungara
islanda
igbo
indonezia
irlandano
itala
Japanoj
la javano
Kannada
kazaĥo
ĥmeroj
Ruando
korea
kurda
Kirgizoj
TB
la latina
latva
litova
luksemburga
makedona
Malgashi
malaja
la malajala
malta
maoria
Maratio
mongola
Mjanmao
nepala
norvega
norvega
okcitana
Paŝto
la persa
pola
portugala
panĝaba
rumana
rusa
samoano
Skotgaela
serba
la angla
Ŝona
Sinda
Sinhala
la slovaka
sloveno
Somalo
hispana
Sundanese
Svahila
sveda
la tagaloga
taĝiko
la tamila
tataro
la telugua
tajlanda
Turka
turkmenoj
ukraina
Urdu
ujgura
uzbeko
vjetnama
kimra lingvo
Helpu
jida
joruboj
la zulua
Gate valve
Working principle: There is a gate opening and closing part inside the valve body. The movement direction of the gate is perpendicular to the direction of the fluid. Because it can block water like a sluice, it is called a gate valve
Advantages and disadvantages: Advantages include small flow resistance; opening and closing are more labor-saving; medium flow direction is not restricted; when fully open, the sealing surface is less eroded by the working medium than the stop valve.
Disadvantages include large external dimensions and opening height, and large space required for installation; during opening and closing, there is relative friction between the sealing surfaces, which is easy to cause scratches; the gate valve has two sealing surfaces, which makes processing, grinding and maintenance more difficult; the opening and closing time is long.

Rising stem gate valve
Difference: The rising stem gate valve has an exposed stem, and the degree of opening and closing is more intuitive, but the stem is also corroded Scope of application: Fire water pump outlet pipe, water suction pipe; outlet pipe, water suction pipe of pressure regulating pump; fire water supply network

Non-rising stem gate valve Difference: Compared with the rising stem gate valve, the non-rising stem gate valve has a non-exposed stem, and the degree of opening and closing is not intuitive, and the installation space is small, which is suitable for concealed projects Scope of application: Fire water pump suction pipe; Fire water supply network

Globe valve
Working principle: Also known as the gate valve, a forced sealing valve, the closing part is driven by the valve stem to move up and down along the center line of the valve seat. The opening or closing stroke of the stop valve is relatively short, and it has a very reliable shut-off action.
Classification of globe valves:
Top threaded stem globe valve
Lower threaded stem globe valve
Straight-through globe valve
Angle globe valve
Three-way globe valve
DC globe valve
Plunger globe valve
Needle globe valve

Advantages and disadvantages of globe valves:
Advantages: The friction of the sealing surface is smaller than that of the gate valve during opening and closing, and it is wear-resistant; the opening height is smaller than that of the gate valve, generally 1/4 of the valve seat diameter; one sealing surface, easy to maintain.
Disadvantages: The flow resistance coefficient is large, causing a large pressure loss; the opening and closing torque is large; the sealing surface may clamp solid particles; pay attention to the inlet and outlet direction when selecting.
Butterfly valve
Working principle: The closing part (valve disc or butterfly plate) is a disc, which rotates around the valve axis to achieve opening and closing.
Scope of application: Fire water pump outlet pipe, water suction pipe; indoor overhead pipeline.
Supplementary explanation: The applicability of butterfly valves is similar to that of gate valves, and some provisions require them to have self-locking functions.
Common installation and use precautions: