86-312-8695888
86-13722963501
info@hbysindustry.com
Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.