86-312-8695888
86-13722963501
info@hbysindustry.com
Affricanaidd
Albaneg
Amhareg
Arabeg
Armenaidd
Azerbaijani
Basgeg
Belarwseg
Bengali
Bosnieg
Bwlgareg
Catalaneg
Cebuano
Corseg
Croateg
Tsiec
Daneg
Iseldireg
Saesneg
Esperanto
Estoneg
Ffinneg
Ffrangeg
Ffriseg
Galiseg
Sioraidd
Almaeneg
Groeg
Gwjarati
Creol Haitaidd
hausa
hawaiian
Hebraeg
Naddo
Miao
Hwngareg
Islandeg
igbo
Indoneseg
gwyddelig
Eidaleg
Japaneaidd
Jafaneg
Kannada
kazakh
Khmer
Rwanda
Corëeg
Cwrdaidd
Kyrgyz
TB
Lladin
Latfieg
Lithwaneg
Lwcsembwrgaidd
Macedoneg
Malgashi
Maleieg
Malayalam
Malteg
Maori
Marathi
Mongoleg
Myanmar
Nepali
Norwyaidd
Norwyaidd
Ocsitaneg
Pashto
Perseg
Pwyleg
Portiwgaleg
Pwnjabi
Rwmania
Rwsiaidd
Samoaidd
Gaeleg yr Alban
Serbeg
Saesneg
Shona
Sindhi
Sinhala
Slofaceg
Slofeneg
Somalïaidd
Sbaeneg
Sundanaidd
Swahili
Swedeg
Tagalog
Tajiceg
Tamil
Tatar
Telugu
Thai
Twrceg
Tyrcmeniaid
Wcrain
Wrdw
Uighur
Wsbeceg
Fietnameg
Cymraeg
Help
Iddeweg
Iorwba
Zwlw
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.