86-312-8695888
86-13722963501
info@hbysindustry.com
afrikano
albana
Amhara
la araba
la armena
Azerbajĝana
eŭska
Belarusian
bengala
bosnia
bulgaro
kataluna
Cebuano
korsika
kroata
ĉeĥa
dana
nederlanda
la angla
Esperanto
estona
finna
franca
frisa
galego
kartvela
germana
greka
Gujaratio
Haitian Creole
hausa
havajano
la hebrea
Ne
Miao
hungara
islanda
igbo
indonezia
irlandano
itala
Japanoj
la javano
Kannada
kazaĥo
ĥmeroj
Ruando
korea
kurda
Kirgizoj
TB
la latina
latva
litova
luksemburga
makedona
Malgashi
malaja
la malajala
malta
maoria
Maratio
mongola
Mjanmao
nepala
norvega
norvega
okcitana
Paŝto
la persa
pola
portugala
panĝaba
rumana
rusa
samoano
Skotgaela
serba
la angla
Ŝona
Sinda
Sinhala
la slovaka
sloveno
Somalo
hispana
Sundanese
Svahila
sveda
la tagaloga
taĝiko
la tamila
tataro
la telugua
tajlanda
Turka
turkmenoj
ukraina
Urdu
ujgura
uzbeko
vjetnama
kimra lingvo
Helpu
jida
joruboj
la zulua
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.