86-312-8695888
86-13722963501
info@hbysindustry.com
africano
albanese
Amarico
Arabo
armeno
Azero
Basco
bielorusso
bengalese
Bosniaco
bulgaro
catalano
Cebuano
Corso
croato
ceco
danese
Olandese
Inglese
esperanto
Estone
finlandese
francese
Frisone
galiziano
georgiano
Tedesco
greco
Gujarati
Creolo haitiano
haussa
hawaiano
ebraico
No
Miao
ungherese
islandese
igbo
indonesiano
irlandesi
Italiano
giapponese
giavanese
Kannada
kazako
Khmer
Ruandese
coreano
curdo
Kirghizistan
TBC
latino
lettone
lituano
Lussemburghese
macedone
Malgashi
malese
Malayalam
maltese
Maori
Marathi
mongolo
Myanmar
nepalese
norvegese
norvegese
occitano
Pashtu
persiano
Polacco
portoghese
Punjabi
rumeno
russo
Samoano
Gaelico Scozzese
serbo
Inglese
Shona
Sindhi
Singalese
slovacco
sloveno
Somalo
spagnolo
Sundanese
Swahili
svedese
Tagalog
Tagico
Tamil
Tartaro
Telugu
tailandese
Turco
turkmeno
ucraino
Urdu
Uiguro
Uzbeco
vietnamita
gallese
Aiuto
yiddish
Yoruba
Zulù
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.