86-312-8695888
86-13722963501
info@hbysindustry.com
africana
albanès
amàric
àrab
armeni
azerbaidjana
basc
Bielorús
bengalí
bosnià
búlgar
català
Cebuà
Cors
croat
txec
danès
holandès
Anglès
esperanto
estonià
finès
francès
frisó
gallec
georgiana
alemany
grec
Gujarati
crioll haitiano
hausa
hawaià
hebreu
No
Miao
hongarès
islandès
igbo
indonesi
irlandesa
italià
japonès
javanès
Kannada
kazakh
Khmer
Ruandès
coreà
kurd
kirguis
TB
llatí
letó
lituà
luxemburguesa
macedoni
Malgashi
Malai
malayalam
maltès
Maori
Marathi
mongol
Myanmar
nepalí
noruec
noruec
occità
Pashto
persa
polonès
portuguès
panjabi
romanès
rus
samoà
Gaèlic escocès
serbi
Anglès
Shona
Sindhi
Sinhala
eslovac
eslovè
Somali
espanyol
Sundanès
suahili
suec
Tagalog
Tadjik
Tamil
Tàrtar
Telugu
tailandès
turc
turcomà
Ucraïnès
Urdú
uigur
Uzbek
vietnamita
gal·lès
Ajuda
Yiddish
ioruba
Zulu
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.