86-312-8695888
86-13722963501
info@hbysindustry.com
afrikane
shqiptare
amharike
arabisht
armene
Azerbajxhani
bask
bjellorusisht
Bengalisht
boshnjake
bullgare
katalanas
Cebuano
korsikane
kroate
çeke
daneze
holandeze
anglisht
Esperanto
estoneze
finlandez
frëngjisht
frizianisht
Galician
gjeorgjiane
gjermanisht
greke
guxharatisht
Kreole Haitiane
hausa
hawajiane
hebraishtja
Jo
Miao
hungareze
islandeze
igbo
indonezisht
irlandeze
italisht
japoneze
javaneze
kanadeze
kazakisht
Khmer
Ruanda
koreane
kurde
Kirgize
TB
latinisht
Letonisht
Lituanisht
luksemburgase
maqedonase
Malgashi
Malay
malajalamisht
malteze
Maori
Marathi
mongolisht
Mianmar
nepalisht
norvegjeze
norvegjeze
Oksitan
Pashto
persisht
polonisht
portugeze
Punjabi
rumun
rusisht
Samoan
gaelishte skoceze
serb
anglisht
Shona
Sindhi
sinhalisht
sllovake
slloven
somalez
Spanjisht
sundanez
Suahili
suedeze
Tagalogisht
Taxhikisht
tamile
tatar
telugu
Thai
turk
turkmen
ukrainase
urdu
ujgure
Uzbekistani
vietnameze
Uellsisht
Ndihmë
Jidish
Jorubisht
Zulu
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.