86-312-8695888
86-13722963501
info@hbysindustry.com
afrikanska
albanska
amhariska
arabiska
armeniska
azerbajdzjanska
baskiska
vitryska
bengaliska
bosniska
bulgariska
katalanska
Cebuano
korsikanska
Kroatisk
tjeckiska
danska
holländska
engelsk
esperanto
estniska
finska
franska
frisiska
galiciska
georgiska
tysk
grekisk
Gujarati
haitisk kreol
hausa
hawaiian
hebreiska
Nej
Miao
ungerska
isländska
igbo
indonesiska
irländsk
italienska
japanska
javanesiska
Kannada
kazakiska
Khmer
rwandiska
koreanska
kurdiska
kirgiziska
TB
latin
lettiska
litauiska
Luxemburgiska
makedonska
Malgashi
malajiska
Malayalam
maltesiska
Maori
Marathi
mongoliska
Myanmar
nepalesiska
norska
norska
occitanska
Pashto
persiska
putsa
portugisiska
Punjabi
rumänska
ryska
Samoan
skotsk gaeliska
serbiska
engelsk
Shona
Sindhi
singalesiska
slovakiska
slovenska
somaliska
spanska
Sundanesiska
Swahili
svenska
Tagalog
tadzjikiska
Tamil
tatariska
Telugu
Thai
turkiska
turkmeniska
ukrainska
Urdu
Uigur
uzbekiska
vietnamesiska
walesiska
Hjälp
jiddisch
Yoruba
Zulu
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.