86-312-8695888
86-13722963501
info@hbysindustry.com
africain
albanais
Amharique
arabe
arménien
azerbaïdjanais
Basque
biélorusse
bengali
bosniaque
bulgare
catalan
Cebuano
Corse
croate
tchèque
danois
Néerlandais
Anglais
espéranto
estonien
finlandais
Français
frison
Galicien
géorgien
Allemand
grec
Gujarati
Créole haïtien
haoussa
hawaïen
hébreu
Non
Miao
hongrois
islandais
igbo
indonésien
irlandais
italien
Japonais
Javanais
Kannada
kazakh
Khmer
Rwandais
coréen
kurde
Kirghize
tuberculose
Latin
letton
lituanien
luxembourgeois
Macédonien
Malgashi
malais
Malayalam
maltais
Maori
Marathi
mongol
Birmanie
Népalais
norvégien
norvégien
Occitan
pachtou
persan
polonais
Portugais
Pendjabi
roumain
russe
Samoan
Gaélique écossais
serbe
Anglais
Shona
Sindhi
Cinghalais
slovaque
slovène
somali
Espagnol
Soundanais
Swahili
suédois
Tagalog
tadjik
Tamil
tatar
Télougou
thaïlandais
turc
Turkmènes
ukrainien
Ourdou
Ouïghour
Ouzbek
vietnamien
gallois
Aide
yiddish
Yorouba
zoulou
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.