86-312-8695888
86-13722963501
info@hbysindustry.com
africano
albanés
amárico
árabe
armenio
azerbaiyano
vasco
bielorruso
bengalí
bosníaco
búlgaro
catalán
Cebuano
corso
croata
checo
danés
holandés
inglés
Esperanto
Estonio
finés
francés
frisona
galego
xeorxiano
alemán
grego
Gujarati
crioulo haitiano
hausa
hawaiano
hebreo
non
Miao
húngaro
islandés
igbo
indonesio
irlandesa
italiano
xaponés
xavanés
Kannada
casco
Khmer
Ruandés
coreano
kurdo
Kirguises
TB
latín
letón
lituano
luxemburgués
macedonio
Malgashi
malaio
malayalam
maltés
maorí
Marathi
mongol
Myanmar
nepalí
noruegués
noruegués
occitano
Pashto
persa
polaco
portugués
Punjabi
romanés
ruso
samoano
Gaélico escocés
serbio
inglés
Shona
Sindhi
cingalés
eslovaco
esloveno
somalí
español
sundanés
suahili
sueco
Tagalo
taxico
Tamil
tártaro
Telugu
tailandés
turco
turcomano
ucraíno
Urdú
uigur
uzbeco
vietnamita
galés
Axuda
yiddish
ioruba
Zulú
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.