86-312-8695888
86-13722963501
info@hbysindustry.com
afrikalı
alban
amhar
ərəb
erməni
Azərbaycan
bask dili
belarus
benqal dili
bosniyalı
bolqar
katalan dili
Cebuano
korsika
xorvat
çex
danimarka
holland
İngilis dili
esperanto
eston
fin
Fransız dili
friz dili
qalisian
gürcü
alman
yunan
qucarat dili
Haiti Kreol
hausa
havaylı
ivrit
Xeyr
Miao
macar
island
igbo
indoneziya dili
irland
italyan
yapon
yava dili
Kannada
qazax
kxmer
Ruanda
koreyalı
kürd
qırğız
Vərəm
latın
latış
litva
Lüksemburq
makedon
Malqaşi
malay
malayalam
maltalı
maori
marati dili
monqol
Myanma
nepal dili
norveçli
norveçli
oksitan
puştu
fars
polyak
portuqal
pəncab dili
rumın
rus
samoa
Şotlandiya Qael dili
serb
İngilis dili
Şona
sindhi
Sinhala
slovak
sloven
Somali
ispan dili
sundan
suahili
isveçli
taqaloq
tacik
tamil
tatar
teluqu dili
Tay
türk
türkmən
ukraynalı
Urdu
uyğur
özbək
vyetnamlı
uels
Kömək edin
yəhudi dili
yoruba
Zulu
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.