86-312-8695888
86-13722963501
info@hbysindustry.com
Afrikaanse
Albanees
Amhaars
Arabisch
Armeens
Azerbeidzjaans
baskisch
Wit-Russisch
Bengaals
Bosnisch
Bulgaars
Catalaans
Cebuano
Corsicaans
Kroatisch
Tsjechisch
Deens
Nederlands
Engels
Esperanto
Ests
Fins
Frans
van Friesland afkomstige
Galicisch
Georgisch
Duits
Grieks
Gujarati
Haïtiaans Creools
huis
Hawaiiaans
Hebreeuws
Nee
Miao
Hongaars
IJslands
igbo
Indonesisch
Iers
Italiaans
Japans
Javaans
Kannada
Kazachs
Khmer
Rwandese
Koreaans
Koerdisch
Kirgizisch
TB
Latijns
Lets
Litouws
Luxemburgs
Macedonisch
Malgashi
Maleis
Malayalam
Maltees
Maori
Marathi
Mongools
Myanmar
Nepalees
Noors
Noors
Occitaans
Pasjto
Perzisch
Pools
Portugees
Punjabi
Roemeense
Russisch
Samoaans
Schots-Gaelisch
Servisch
Engels
Shona
Sindhi
Singalees
Slowaaks
Sloveens
Somalisch
Spaans
Soendanees
Swahili
Zweeds
Tagalog
Tadzjiekse
Tamil
Tataars
Telugu
Thais
Turks
Turkmeens
Oekraïens
Urdu
Oeigoerse
Oezbeeks
Vietnamees
Welsh
Hulp
Jiddisch
Joruba
Zoeloe
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.