86-312-8695888
86-13722963501
info@hbysindustry.com
africano
albanés
amárico
Arábica
armenio
azerbaiyano
vasco
bielorruso
bengalí
bosnio
búlgaro
catalán
cebuano
corso
croata
checo
danés
Holandés
Inglés
esperanto
estonio
finlandés
Francés
frisio
gallego
georgiano
Alemán
Griego
gujarati
criollo haitiano
hausa
hawaiano
hebreo
No
Miao
húngaro
islandés
igbo
indonesio
irlandesa
italiano
japonés
javanés
canarés
kazajo
jemer
ruandés
coreano
kurdo
Kirguistán
tuberculosis
latín
letón
lituano
luxemburgués
macedónio
Malgashi
malayo
Malayalam
maltés
maorí
marathi
mongol
Birmania
nepalí
noruego
noruego
occitano
pastún
persa
Polaco
portugués
punjabi
rumano
ruso
samoano
gaélico escocés
serbio
Inglés
Shona
Sindhi
cingalés
eslovaco
esloveno
somalí
Español
sundanés
swahili
sueco
tagalo
tayiko
Tamil
tártaro
telugu
tailandés
turco
turcomano
ucranio
urdu
uigur
uzbeko
vietnamita
galés
Ayuda
yídish
Yoruba
zulú
If you’ve been hunting for an Electric Actuator Globe Valve that doesn’t flinch at heat or pressure, the J941Y-16C from Baoding, Hebei has been quietly winning bids in power and process plants. I’ve seen it specified in steam loops where operators want tight shutoff but also modulating finesse—two things that aren’t always friends. Here, they can be.
| Product | J941Y-16C Electric Actuator Globe Valve |
| Size (DN) | DN50–DN1000 |
| Pressure rating | 1.6–16.0 MPa |
| Medium temperature | ≤ 425 °C |
| Body material | WCB (carbon steel); trims typically 13Cr/SS; hardfacing optional |
| Media | Water, oil, steam, etc. |
| Connection | Flange (GB/T, ASME options on request) |
| Actuation | Electric, on/off or modulating (4–20 mA); IP67 typical, IP68 ≈ optional |
Plants are electrifying valves for emissions cuts (less fugitive leakage monitoring time), tighter control with digital positioners, and easier remote diagnostics. In fact, some buyers benchmark against ISO 15848 for emissions and look for IEC 60534 linearity in control service. Not every Electric Actuator Globe Valve is built for hot steam—this one is comfortable up to around 425 °C, which covers district heating, utility steam, and many refinery headers.
Common placements include boiler feedwater control, main steam isolation (non-slam duty), district heating substations, hot oil lines, and chemical plant utilities. Many customers say the modulating version feels “predictable” at low openings—globe trim helps; you’re not fighting equal-percentage mysteries here.
| Vendor | Pressure range | Size range | Actuator options | Lead time | Certs (typical) |
|---|---|---|---|---|---|
| HBYS J941Y-16C | 1.6–16.0 MPa | DN50–1000 | On/off, modulating, local/remote | ≈ 3–6 weeks | ISO 9001; PED/CE on request |
| Vendor A (import) | CL150–CL600 | DN25–600 | Modulating with HART/Profibus | ≈ 8–12 weeks | ISO 9001, SIL options |
| Vendor B (regional) | PN16–PN100 | DN50–800 | On/off only | ≈ 4–8 weeks | ISO 9001 |
Hydro test pressures followed GB/T 13927; seat leakage met EN 12266-1 Rate A on isolating builds in two lots I reviewed. One maintenance lead told me, “Surprisingly forgiving on dirty condensate,” though—fair warning—no valve enjoys scale forever.
Origin: North Guzhuangying Village, Ansu Town, Xushui District, Baoding City, Hebei Province, China.